FAQ / X Series / X2 4K Output Issues
X2 HDMI outboard 4K output issues
VENUS X2 HDMI outboard 4K output issues
Overview
The source FAQ describes two board-level output faults on VENUS X2 HDMI output board hardware version V1.2. These are service-level hardware notes, not normal operator menu adjustments.
Applies to
VENUS X2 4HDMI output board V1.2
Symptom 1
Some 4K displays show no picture at 2048 x 1152 @ 60 Hz.
Source diagnosis
- GENLOCK signal quality is not good.
Source remedy
- Modify capacitor C360 to 10pF.
- Leave resistor R482 as NC.
- Modify resistor R508 to 0R.
Symptom 2
Some 4K monitors show no picture and report a resolution that does not match the configured output.
Source diagnosis
- HS and VS signal quality is not good.
Source remedy
- Modify resistors R484 and R485 from 0R to 100R.
Important note
- These are hardware rework instructions tied specifically to V1.2 board revisions. Treat them as bench-service actions, not field UI troubleshooting.