API / mini-extreme ISO API / exm 0x00 Set Output Resolution

mini-extreme ISO: Set The Output Resolution of The Output Port

SymbolDefinitionRemarks
Start bit<The command uses "<" as the start bit
TransmitT
ADDR0x00
SN0x00
CMD0x74
DAT10x00Set the output resolution; see API / REFERENCE / RESOLUTION for the resolution table
DAT20x00-0xFFOutput port, 0x00 global by default
DAT3Low byte of the resolution value
DAT4High byte of the resolution value
CHKSUMCheck sum = ADDR + SN + CMD + DAT1 + DAT2 + DAT3 + DAT4
End bit>The command uses ">" as the end bit

Command list

Query the global standard output resolutionStart bitInstruction TypeAddressSNCommandData 1Data 2Data 3Data 4ChecksumEnd bit
Set the standard output resolution<T00007400010A007F>

Application example

FunctionSend & readbackResult
Set the output resolution of output port 2 to: 1920*1080@60<T00007400010A007F>
<F00007400010A007F>Set successfully the global resolution is: 1920x1080@60