API / mini-extreme ISO API / exm 0x02/0x03 Signal Switch

mini-extreme ISO: 0x02/0x03 Signal Source Switching Setting

SymbolDefinitionRemarks
Start bit<The command uses "<" as the start bit
TransmitT
ADDR0x00
SN0x00
CMD0x75
DAT10x02-0x030x02 (set), 0x03 (query)
DAT20x00Not used
DAT30x00-0x03Input port 0-N (the input ports depend on the actual device, e.g. for mini pro N = 3)
DAT40x000x00: pst; 0x01: pgm
CHKSUMCheck sum = ADDR + SN + CMD + DAT1 + DAT2 + DAT3 + DAT4
End bit>The command uses ">" as the end bit

Command list

Signal source switching settingStart bitInstruction TypeAddressSNCommandData 1Data 2Data 3Data 4ChecksumEnd bit
Signal source switching input 1<T0000750200000077>
Signal source switching input 2<T0000750200010078>
Signal source switching input 3<T0000750200020079>
Signal source switching input 4<T000075020003007A>
Signal source switching PVW<T000075020004007B>
Signal source switching PGM<T000075020004017C>

Application example

FunctionSend & readbackResult
Set input channel 3 to output channel 5<T0000750200000077>
<F0000750200000077>Set successfully