API / Commands / Load Scene/Bank

Load Scene/Bank

Load Scene/Bank

Overview

To load/recall saved scene

Device Supported

Q Series: Q16pro Gen 2

X Series: X2, X3, X7, X8, X14

Command Structure

ElementAttributeDetail
HEAD<
TYPET
ADDR0x00default
SEQN0x00default
CMMD0x68
DAT10x18Load scene
DAT20x00~0x0FScene number 1~16
DAT30x00Unused
DAT40x00Unused
CHKSCheck sum=ADDR+SN+CMD+DAT1+DAT2+DAT3+DAT4
END>

TAKE command must be invoked after each Load scene command.

TAKE command for Q series and X series as below:

  • Q series Group TAKE

<T0000F0380005002D>0200000002

  • X series TAKE
<T0000780000000078>

Example Transmit

  • Load scene 10
CommandHEADTYPEADDRSEQNCMMDDAT1DAT2DAT3DAT4CHKSEND
ASCII<T0000681809000089>
HEX3C5430 3030 3036 3831 3830 3930 3030 3038 393E

Command Sample

<T0000681807000087>//Load scene 8 <T0000F0380005002D>0200000002//group TAKE <F0000681807000087> <F0000F0380006012F>//feedback: Load scene 8 successfully

Reference