FAQ / VSP Processors / VSP 729 Remote Control
VSP 729 RS232 remote control basics
VSP 729 RS232 remote control basics
Applies to
VSP 729
Overview
VSP 729 can be controlled remotely over RS232. Use the Open API documentation for the full protocol reference.
Common commands
Set input source
| Output channel | CV1 | CV2 | YPbPr | VGA | DVI |
|---|---|---|---|---|---|
| 1 | <T0100720001000074> | <T0100720002000075> | <T0100720004000077> | <T0100720005000078> | <T0100720006000079> |
| 2 | <T0200720001000075> | <T0200720002000076> | <T0200720004000078> | <T0200720005000079> | <T020072000600007A> |
| 3 | <T0300720001000076> | <T0300720002000077> | <T0300720004000079> | <T030072000500007A> | <T030072000600007B> |
| 4 | <T0400720001000077> | <T0400720002000078> | <T040072000400007A> | <T040072000500007B> | <T040072000600007C> |
Select preview channel
| Channel/output | Code |
|---|---|
| 1 | <T00029038010000CB> |
| 2 | <T00039038020000CD> |
| 3 | <T00039038030000CE> |
| 4 | <T00039038040000CF> |
Take or cut to output
| Action | Code |
|---|---|
| CUT | <T0005902A010000C0> |
| TAKE | <T0002902A000000BC> |