API / mini Series API / 0x00 Set Output Resolution
Set The Output Resolution of The Output Port
Applicable Devices : mini-pro, mini-pro V3, mini v3, mini-ISO, mini-edge SDI, mini-mx SDI, mini-max, mini-extreme ISO
| Symbol | Definition | Remarks |
|---|---|---|
| Start bit | < | The command uses "<" as the start bit |
| Transmit | T | |
| ADDR | 0x00 | |
| SN | 0x00 | |
| CMD | 0x74 | |
| DAT1 | 0x00 | Set the output resolution; see API / REFERENCE / RESOLUTION for the resolution table |
| DAT2 | 0x00-0xFF | Output port, 0x00 global by default |
| DAT3 | Low byte of the resolution value | |
| DAT4 | High byte of the resolution value | |
| CHKSUM | Check sum = ADDR + SN + CMD + DAT1 + DAT2 + DAT3 + DAT4 | |
| End bit | > | The command uses ">" as the end bit |
Command list
| Query the global standard output resolution | Start bit | Instruction Type | Address | SN | Command | Data 1 | Data 2 | Data 3 | Data 4 | Checksum | End bit |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Set the standard output resolution | < | T | 00 | 00 | 74 | 00 | 01 | 0A | 00 | 7F | > |
Application example
| Function | Send & readback | Result |
|---|---|---|
| Set the output resolution of output port 2 to: 1920*1080@60 | <T00007400010A007F> | |
| <F00007400010A007F> | Set successfully the global resolution is: 1920x1080@60 |