FAQ / RGB20X-NAI-GY / VISCA/PELCO Control

VISCA/PELCO Control Not Working

  • Ensure that the protocol is enabled and matches the controller requirements.

  • Verify that the configured port matches the controller settings.

  • The default VISCA port is 1259.

    Do not use ports 5000, 5002, 554, 80, 88, 8080, or 9005, as they are reserved by the camera's internal services.

  • Click Save and reboot the camera after changing the settings.